Scenario 61: VM Network Adapter Type Mismatch Leading to Throughput & Latency Issues


In a virtualised environment, several Windows and Linux VMs were upgraded from older hardware generations. However, their virtual network adapters remained at legacy types (e.g., E1000 instead of VMXNET3). Over time, network-intensive applications (like database replication, file transfers) began showing higher latency and reduced throughput compared to peers. The virtualization blog on common VMware issues lists outdated network devices as a frequent culprit.

Symptoms:


VMs show network throughput significantly lower than expected (e.g., 1-2 Gbps when 10 Gbps uplinks are available).

Guest OS logs/reporting show generic network adapter or missing driver warnings.

Traffic from those VMs shows higher packet latency or retransmissions.


Root cause analysis:

Virtual machines benefit from modern para-virtualised network adapters (VMXNET3) which provide high throughput and low latency. If VMs are still using legacy network adapters (e.g., E1000) after upgrade, they may not be taking advantage of the host’s network fabric. The mismatched adapter type becomes a bottleneck.


Troubleshooting steps:


Identify VMs using legacy network adapter types: check VM settings for network adapter version/type.

For affected VMs, in guest OS check device manager (Windows) or lspci/ethtool (Linux) to see if drivers correspond to optimal adapter.

Compare network performance metrics (throughput, latency) between VMs with new vs old adapter types.

Validate that the host physical network and virtual switch support the desired adapter type (e.g., VMXNET3).


Solution:

Upgrade network adapter type for affected VMs to VMXNET3 (or equivalent modern type) and install the appropriate guest OS drivers.

If performing a hardware-version upgrade, include network adapter upgrade in the process.

Monitor throughput/latency post-upgrade to validate improvement.

Maintain an inventory/checklist of VMs still using legacy adapters and schedule upgrades.

Scenario 62: Time-Sync / NTP Mis-Configuration Leading to Authentication Failures & VM Guest Crashes


A VMware cluster began encountering sporadic guest OS authentication failures and time-sensitive applications (e.g., Kerberos) reported errors. In parallel, some VMs displayed time drift, causing business applications to misbehave or silently fail. On investigation, the hosts and VMs were not consistently synchronised to NTP, and some had no time source set. Time drift in virtualised environments is often overlooked yet frequently causes issues.

Symptoms:


Guest OS logs show time mismatch warnings or Kerberos authentication errors (KRB5KRB_AP_ERR_TKT_EXPIRED, etc).

Virtual machines show noticeable clock drift when compared to host/physical time.

Applications with time-based licensing or synchronization fail intermittently.


Root cause analysis:

Time synchronization in virtual environments is critical. ESXi hosts should synchronise to NTP or other reliable time sources, and virtual machines should see accurate clock (either via VMware Tools, hardware clock or NTP). When host/guest time diverge, authentication, licensing, replication and clustered services may fail. Because many articles highlight resource or configuration issues as root causes in VMware environments, time-sync mis-config falls into that category.


Troubleshooting steps:


Check ESXi host NTP configuration (vSphere → Host > Manage > Time & Location) and that time service is running and synced to a reliable server.

For each VM, check guest OS date/time and compare with host/physical time.

Check VMware Tools in VMs: whether time sync with host is enabled/disabled — guest OS may need its own NTP if heavy time-sensitive apps.

Review logs for authentication errors, time mismatch events, or license-related failures.


Solution:

Standardise NTP configuration across all hosts and management components; ensure hosts sync to high-quality time sources.

Configure VMs appropriately: for critical apps, consider disabling guest-host time sync and instead rely on guest OS NTP.

Monitor clock drift across hosts/VMs; set alerts for δ > X seconds.

Include time-sync checks in scheduled health-checks.


Scenario 63: VM Hardware Version Mismatch Across Hosts Preventing vMotion & DRS Efficiency


In a multi-host cluster, some hosts were upgraded earlier than others. Some VMs had been upgraded to newer virtual hardware version (VM compatibility level). When DRS attempted to migrate VMs, some migrations failed or targeted hosts couldn’t support the hardware version. Over time, this mismatch reduced the effectiveness of DRS/vMotion and increased manual overhead. Compatibility mismatch is frequently cited in VMware admin problem-lists.


Symptoms:

vMotion or DRS migration tasks fail with errors referencing “hardware version incompatible” or “host does not support virtual hardware version”.

Hosts show VMs with higher virtual hardware version than host’s maximum supported.

DRS balancing is limited or fails for certain VMs; manual migrations needed.


Root cause analysis:

Each VM has a hardware compatibility version (virtual hardware version). Hosts must support that version to run or migrate that VM. If you have hosts at differing ESXi versions or hardware capabilities, VMs upgraded to latest hardware version may not be migratable across all hosts. This reduces cluster flexibility.


Troubleshooting steps:

For each VM, check virtual hardware version (in VM summary tab).

For each host, check maximum supported VM hardware version (host version and HCL).

Review migration failure logs: note error messages about hardware version unsupported.

Inventory cluster: hosts with different major versions or capabilities; note which VMs reside on which hosts.


Solution:

Harmonise host versions across cluster or segregate hosts into compatibility pools.

Plan VM hardware version upgrades in controlled batches: identify host compatibility first.

For VMs needing migration flexibility, avoid upgrading to a hardware version unsupported by all hosts in cluster.

Use automation/inventory to report VMs with hardware version higher than cluster minimum.

=======================================================================


Scenario 64: Storage Path Failover Not Configured Leading to I/O Interruptions During Maintenance


During storage array maintenance, one host experienced I/O timeouts and some VMs became unresponsive until the maintenance window ended. The root cause was that storage path failover/multipathing wasn’t correctly configured on the ESXi host, so when one storage path (HBA/FC link) was taken offline, alternate paths weren’t used. Storage path failover and multipathing mis-config is highlighted frequently in VMware troubleshooting discussions.


Symptoms:


During scheduled storage maintenance or fail-over of one path/link, certain hosts show I/O errors, VMs hang or become slow.

In host logs: SCSI path down or device unreachable errors.

In vCenter: datastore shows reduced accessibility or host alarms for storage path loss.


Root cause analysis:

Shared storage in VMware environments typically requires multiple physical paths and correct multipathing configuration. If a path is disabled or fails (for maintenance/upgrade), hosts must automatically switch to alternate paths to maintain access. If that doesn’t happen because of mis-config, I/O interruption results. Storage path issues are consistently among top virtualization issues.


Troubleshooting steps:

On host: esxcli storage nmp device list or esxcli storage core path list to review current paths for each datastore.

Confirm each LUN/datastore has more than one active path and that path states are “Active”.

Review host logs for path failures or “lost paths” during maintenance windows.

Check multipathing policy (Round Robin, Fixed) and ensure vendor best-practices applied.


Solution:

Configure and test storage multipathing: at least two physical paths per datastore, correct multipathing policy, and active/standby states.

Before maintenance, verify check of path redundancy for all hosts; schedule hosts migration if any host uses only one path.

Monitor storage path state and set alerts for “Only one path active” or “path down”.


Scenario 65: VM Memory Overcommit with No Reservation Leads to Performance Degradation Under Load

A consolidation initiative increased VM density on hosts (more VMs per host) but didn’t adjust memory reservations or monitor guest-ballooning. After a seasonal peak workload, several VMs suffered high memory swap/balloon events, performance dropped, and guest OS paging increased. Memory overcommit and mis-reservation are frequently listed in VMware troubleshooting guidance.


Symptoms:

Host memory consumption appears moderate, but several VMs slow down with high guest OS paging or balloon events.

VM performance charts: memory ballooning spikes, swapped memory increases, “Consumed vs Active” metrics diverge.

Applications inside those VMs show delayed response, increased latency, or timeouts.


Root cause analysis:


In virtualised hosts, memory overcommitment allows allocation above physical RAM. If reservations or limits are not configured and too many VMs compete for memory, hypervisor may need to reclaim memory via balloon driver or swap, which significantly degrades performance. Resource constraints are identified as major virtualization issues.


Troubleshooting steps:

In vCenter, inspect host memory usage and VM memory metrics: “Ballooned Memory”, “Swapped Memory”, “Consumed vs Active”.

Identify VMs with high balloon/swap and correlate to guest OS paging/swap usage.

Check resource-pool settings: are reservations/limits correctly assigned or missing?

Review host density: number of VMs per host vs memory headroom and planned peak loads.


Solution:


Right-size VMs: allocate memory based on actual usage rather than just “maximum”.

Define and apply reservations/limits/shares for VMs based on priority. Critical VMs should have reservations to avoid ballooning.

Monitor host memory usage and alerts for balloon/swap crossing thresholds.

Adjust consolidation ratio if load peaks cannot be absorbed without performance drop.

======================================================================


Scenario 66: VM Network Adapter Type Mismatch Leading to Throughput & Latency Issues

In a virtualised environment, several Windows and Linux VMs were upgraded from older hardware generations. But their virtual network adapters remained an older type (e.g., E1000) rather than the optimal para-virtualised type (VMXNET3). Over time, network-intensive applications (file transfers, replication) showed higher latency and reduced throughput, whereas others on the same host performed fine.


Symptoms:

VMs show network throughput significantly lower than expected despite 10 Gb uplinks.

Guest OS logs indicate generic network adapter driver or warnings.

Traffic from those VMs shows higher packet latency or retransmissions.


Root cause analysis:

Using legacy network adapter types inside VMs means they don’t take full advantage of modern host/virtual switch capabilities. The mismatch between VM adapter type and the underlying fabric becomes a bottleneck. Articles on common VMware issues show “outdated VM network devices” as a frequent cause of performance lag.

Troubleshooting steps:

Identify VMs using legacy adapter types (check VM settings → network adapter).

For affected VMs, check guest OS device manager (Windows) or lspci / ethtool (Linux) to see network adapter type/driver.

Compare network throughput/latency metrics between VMs with old vs new adapters.

Validate the host physical and virtual switching infrastructure supports the newer adapter type (VMXNET3) and is configured accordingly.


Solution:


Upgrade network adapter type for affected VMs to VMXNET3 (or equivalent), install/update the guest OS driver accordingly.

During virtual hardware version upgrades, include network adapter upgrade as part of the plan.

Monitor throughput/latency post-upgrade to validate improvement.

Maintain an inventory/list of VMs still using legacy adapters and schedule remediation.

Scenario 67: Time-Sync / NTP Mis-Configuration Leading to Authentication Failures & VM Guest Crashes

A vSphere cluster began showing sporadic guest OS authentication failures and time-sensitive applications reported errors (like Kerberos tickets expired). Some VMs drifted in time compared to the host or other services, causing unexpected application behavior (licensing, replication). Investigation found hosts and VMs lacked consistent NTP/time synchronization.


Symptoms:

Guest OS logs show time mismatch warnings or authentication failures (e.g., Kerberos KRB5KRB_AP_ERR_TKT_EXPIRED).

VMs show noticeable clock drift when compared to host/physical time.

Time-based applications or clustered services fail intermittently or behave in inconsistent ways.


Root cause analysis:

Time synchronization is often overlooked in virtualised environments. Hosts must sync to reliable NTP servers, and guests must either rely on host time or their own sources depending on workload. When time drifts too far, authentication, replication, clustering and licensing frequently fail. The general “resource/ configuration” category of issues applies.

Troubleshooting steps:

Check ESXi host time/NTP configuration: vSphere → Host → Manage → Time & Location.

For each VM, check guest OS date/time and compare to host/actual time.

Check whether VMware Tools time-sync with host is enabled or disabled; determine if guest OS should use its own NTP.

Review logs for authentication/time mismatch events (guest and host).


Solution:


Standardise NTP configuration across all hosts; ensure reliable time sources.

Decide on a time-sync strategy for guests: host-sync vs dedicated NTP inside VM depending on application.

Monitor clock drift across hosts/VMs; alert when drift > X seconds.

Include time-sync check in regular health-checks and upgrade/maintenance checklists.

========================================================================


Scenario 68: VM Hardware Version Mismatch Across Hosts Preventing vMotion & DRS Efficiency

In a cluster with heterogeneous hosts (some upgraded earlier than others), some VMs had virtual hardware version upgraded to the latest compatibility level. When DRS tried to migrate VMs, it failed for certain hosts because they didn’t support the newer hardware version. Over time, this reduced cluster flexibility and manual migrations increased. Compatibility mismatch is a common issue.

Symptoms:

vMotion or DRS migrations fail with errors like “Hardware version incompatible” or “Host does not support VM hardware version”.

Hosts show VMs whose hardware version is higher than host maximum supported.

DRS balancing is incomplete or fails to migrate certain VMs.

Root cause analysis:

Virtual machine hardware version (virtual hardware compatibility) defines vCPU, vMemory, device support. Hosts must support that version for migration or operation. If some hosts are behind, VMs upgraded too far may become locked to certain hosts, reducing mobility.


Troubleshooting steps:

For each VM: review virtual hardware version in VM summary tab.

For each host: check supported virtual hardware versions (via HCL/documentation).

Review migration failure logs for hardware version errors.

Inventory cluster: hosts with mismatched versions and VMs assigned accordingly.


Solution:

Harmonies host versions across cluster or segment hosts into compatibility pools.

Plan VM hardware version upgrades only after verifying host support.

Prioritize upgrading hosts hardware/firmware to support desired VM version.

Use automation/inventory tools to flag VMs with hardware version higher than minimum host version.

=======================================================================


Scenario 69: Storage Path Fail-over Not Configured Leading to I/O Interruptions During Maintenance


During planned storage array maintenance (one path disabled), one ESXi host experienced I/O timeouts and VMs hung. The investigation revealed the host lacked proper multipathing configuration, and when the primary path went offline, no alternate path was active. Storage path fail-over mis-configuration is a frequent VMware admin headache.


Symptoms:


During storage maintenance, some hosts show I/O errors and VMs become unresponsive.

ESXi logs contain “path down” or “device unreachable” errors.

In vCenter, datastore shows alarms or reduced accessibility for certain hosts.


Root cause analysis:

Shared storage in VMware environments requires multiple physical paths for redundancy. Without correct multipathing and path failover configuration, maintenance or path failure leads to host I/O interruption. One of the “top issues” for VMware admins is hardware/firmware/driver compatibility including storage paths.



Troubleshooting steps:

On host: esxcli storage core path list or esxcli storage nmp device list to review per-LUN path count and status.

Ensure each datastore has more than one active path and alternate paths ready.

Review host logs for path failure events and time when maintenance occurred.

Check storage multipathing policy (Round Robin, Fixed) and vendor best practices.


Solution:

Configure correct multipathing: at least two physical paths per datastore, enabled path failover, correct policy.

Before maintenance, verify each host’s path redundancy; if not, migrate VMs or update configuration.

Monitor path status and alert when only a single path is active.

=====================================================================


Scenario 70: VM Memory Over-commit Without Reservations Leads to Degraded Performance Under Load


In a consolidation push, the operations team increased number of VMs per host to maximise utilisation—but did not configure memory reservations or monitor ballooning. When a peak workload occurred, several VMs experienced severe memory ballooning and swapping, guest OS paging increased, and performance degraded. Memory overcommit and missing reservations are widely identified issues.


Symptoms:

Host memory consumption appears moderate, yet some VMs slow down with high guest OS paging or balloon driver activity.

VM performance charts show spike in “Ballooned memory” or “Swapped memory”.

Applications inside VMs show delays or timeouts.


Root cause analysis:

Memory overcommit allows more memory to be allocated than physical RAM, but without reservations or proper configuration, under load the hypervisor uses ballooning/swapping, degrading performance. Resource constraints/bottlenecks are among the top issues listed for VMware admins.


Troubleshooting steps:

In vCenter: check host and VM memory metrics (“Ballooned Memory”, “Swapped Memory”, “Consumed vs Active”).

Identify which VMs are ballooning or swapping heavily; correlate with guest OS paging/swap.

Check resource-pool settings: what are the reservation/limit/share settings? Are default/unlimited?

Review host consolidation ratio: number of VMs, memory assigned vs physical memory available.


Solution:

Right-size VMs: allocate memory based on actual usage rather than maximum possible.

Configure memory reservations for critical VMs to guarantee memory availability.

Monitor balloon/swap metrics and set alerts for thresholds exceeded.

Consider reducing VM density per host if memory pressure cannot be relieved.

========================================================================

Scenario 71: VM Network Adapter Type Mismatch Leading to Throughput & Latency Issues

In a virtualised environment, several Windows and Linux VMs were upgraded from older hardware generations. But their virtual network adapters remained an older type (e.g., E1000) rather than the optimal para-virtualised type (VMXNET3). Over time, network-intensive applications (file transfers, replication) showed higher latency and reduced throughput, whereas others on the same host performed fine. Issues like “Outdated VM network devices” are identified in VMware-issue summaries.


Symptoms:

VMs show network throughput significantly lower than expected despite 10 Gb uplinks.

Guest OS logs indicate generic network adapter driver or warnings.

Traffic from those VMs shows higher packet latency or retransmissions.


Root cause analysis:

Using legacy network adapter types inside VMs means they don’t take full advantage of modern host/virtual switch capabilities. The mismatch between VM adapter type and the underlying fabric becomes a bottleneck.


Troubleshooting steps:


Identify VMs using legacy adapter types (check VM settings → network adapter).

For affected VMs, check guest OS device manager (Windows) or lspci / ethtool (Linux) to see network adapter type/driver.

Compare network throughput/latency metrics between VMs with old vs new adapters.

Validate the host physical and virtual switching infrastructure supports the newer adapter type (VMXNET3) and is configured accordingly.


Solution:


Upgrade network adapter type for affected VMs to VMXNET3 (or equivalent), install/update the guest OS driver accordingly.

During virtual hardware version upgrades, include network adapter upgrade as part of the plan.

Monitor throughput/latency post-upgrade to validate improvement.

Maintain an inventory/list of VMs still using legacy adapters and schedule remediation.

====================================================================


Scenario 72: Time-Sync / NTP Mis-Configuration Leading to Authentication Failures & VM Guest Crashes.A vSphere cluster began showing sporadic guest OS authentication failures and time-sensitive applications reported errors (like Kerberos tickets expired). Some VMs drifted in time compared to the host or other services, causing unexpected application behaviour (licensing, replication). On investigation, hosts and VMs lacked consistent NTP/time synchronisation.


Symptoms:

Guest OS logs show time mismatch warnings or authentication failures (e.g., Kerberos KRB5KRB_AP_ERR_TKT_EXPIRED).

VMs show noticeable clock drift when compared to host/physical time.

Time-based applications or clustered services fail intermittently or behave in inconsistent ways.


Root cause analysis:

Time synchronisation is often overlooked in virtualised environments. Hosts must sync to reliable NTP servers, and guests must either rely on host time or their own sources depending on workload. When time drifts too far, authentication, replication, clustering and licensing frequently fail.


Troubleshooting steps:

Check ESXi host time/NTP configuration: vSphere → Host → Manage → Time & Location.

For each VM, check guest OS date/time and compare to host/actual time.

Check whether VMware Tools time-sync with host is enabled or disabled; determine if guest OS should use its own NTP.

Review logs for authentication/time mismatch events (guest and host).


Solution:

Standardize NTP configuration across all hosts; ensure reliable time sources.

Configure VMs appropriately: for critical apps, consider disabling guest-host time sync and instead rely on guest OS NTP.

Monitor clock drift across hosts/VMs; alert when drift > X seconds.

Include time-sync check in regular health-checks and upgrade/maintenance checklists.

===================================================================


Scenario 73: VM Hardware Version Mismatch Across Hosts Preventing vMotion & DRS Efficiency


In a cluster with heterogeneous hosts (some upgraded earlier than others), some VMs had virtual hardware version upgraded to the latest compatibility level. When DRS tried to migrate VMs, some migrations failed or targeted hosts couldn’t support the newer hardware version. Over time, this reduced cluster flexibility and manual migrations increased.


Symptoms:

vMotion or DRS migrations fail with errors like “Hardware version incompatible” or “Host does not support VM hardware version”.

Hosts show VMs whose hardware version is higher than host maximum supported.

DRS balancing is incomplete or fails for certain VMs.


Root cause analysis:

Virtual machine hardware version (virtual hardware compatibility) defines vCPU, vMemory, device support. Hosts must support that version for migration or operation. If some hosts are behind, VMs upgraded too far may become locked to certain hosts, reducing mobility.


Troubleshooting steps:

For each VM: review virtual hardware version in VM summary tab.

For each host: check supported virtual hardware versions (via HCL/documentation).

Review migration failure logs for hardware version errors.

Inventory cluster: hosts with mismatched versions and VMs assigned accordingly.


Solution:

Harmonise host versions across cluster or segment hosts into compatibility pools.

Plan VM hardware version upgrades only after verifying host support.

For VMs needing migration flexibility, avoid upgrading to a hardware version unsupported by all hosts in cluster.

Use automation/inventory to flag VMs with hardware version higher than cluster minimum.

=============================================================

Scenario 74 Storage Path Fail-over Not Configured Leading to I/O Interruptions During Maintenance

During planned storage array maintenance (one path disabled), one ESXi host experienced I/O timeouts and VMs hung. The investigation revealed the host lacked proper multipathing configuration, and when the primary path went offline, no alternate path was active. Storage path fail-over mis-configuration is a frequent issue.


Symptoms:


During storage maintenance, some hosts show I/O errors and VMs become unresponsive.

ESXi logs contain “path down” or “device unreachable” errors.

In vCenter, datastore shows alarms or reduced accessibility for certain hosts.


Root cause analysis:

Shared storage in VMware environments requires multiple physical paths and correct multipathing configuration. Without correct fail-over, maintenance or path failure leads to host I/O interruption. Storage path issues are top-tier in virtualization troubleshooting.


Troubleshooting steps:

On host: esxcli storage core path list or esxcli storage nmp device list to review per-LUN path count/state.

Ensure each datastore has more than one active path and alternate paths are ready.

Review host logs for path failure events and time when maintenance occurred.

Check storage multipathing policy (Round Robin, Fixed) and vendor best practices.


Solution:


Configure correct multipathing: at least two physical paths per datastore, active/standby, correct policy.

Before maintenance, verify each host’s path redundancy; migrate VMs or update if only one path.

Monitor path state and send alerts when only a single path active.

========================================================================


Scenario 75: VM Memory Over-commit Without Reservations Leads to Degraded Performance Under Load


In a consolidation push, the operations team increased number of VMs per host to maximise utilisation—but did not configure memory reservations or monitor ballooning. When a seasonal peak workload occurred, several VMs experienced severe memory ballooning and swapping, guest OS paging increased, and performance degraded. Memory over-commit and missing reservations are widely identified issues.


Symptoms:


Host memory consumption appears moderate, yet some VMs slow down with high guest-OS paging or balloon driver activity.

VM performance charts: spike in “Ballooned Memory” or “Swapped Memory”.

Applications inside VMs show delays or timeouts.


Root cause analysis:

Memory over-commitment allows more memory to be allocated than physical RAM, but without reservations or proper configuration, under load the hypervisor uses ballooning/swapping, degrading performance. Resource constraints/bottlenecks are among the top issues.


Troubleshooting steps:

In vCenter: check host and VM memory metrics (“Ballooned Memory”, “Swapped Memory”, “Consumed vs Active”).

Identify which VMs are ballooning/swapping heavily; correlate with guest OS paging/swap.

Check resource-pool settings: reservation/limit/share settings – are default/unlimited?

Review host consolidation ratio: number of VMs vs memory assigned vs physical memory.


Solution:

Right-size VMs: allocate memory based on actual usage rather than maximum possible.

Configure memory reservations for critical VMs to guarantee availability.

Monitor balloon/swap metrics and alert when crossing threshold.

Consider reducing VM density per host if memory pressure remains.

======================================================================


Scenario 76: VM Network Adapter Type Mismatch Leading to Throughput & Latency Issues


In a virtualised environment, several Windows and Linux VMs were upgraded from older hardware generations. But their virtual network adapters remained an older type (for example, E1000) rather than the optimal para-virtualised type such as VMXNET3. Over time, network-intensive applications (file transfers, replication) showed higher latency and reduced throughput, while other VMs on the same host performed fine.


Symptoms:

VMs on older adapter types show network throughput significantly lower than expected—even though the host physical network is ample.

Guest OS logs/reporting show generic network adapter driver or warnings.

Traffic from those VMs shows higher packet latency or retransmissions.


Root cause analysis:

Outdated or mismatched network adapter types inside VMs prevent them from fully leveraging the host’s network and virtual switch capabilities. Virtualisation-related resources point to “outdated VM network devices” as a common issue.


Troubleshooting steps:


Identify VMs still using legacy network adapter types (check VM settings ⇒ network adapter type).

For affected VMs: inspect guest OS network adapter driver type (Windows Device Manager or lspci/ethtool in Linux).

Compare network performance (throughput/latency) between VMs with old vs new adapter types.

Validate that the host’s virtual switch and physical NIC network fabric support the newer adapter type and that drivers are up to date.


Solution:


Upgrade the network adapter type of the affected VMs to VMXNET3 or equivalent, and install/update the appropriate guest OS drivers.

During hardware/version upgrades, include network adapter type review and migration as a step.

After upgrade, monitor throughput/latency to confirm improvement.

Maintain an inventory/report of VMs still using older network adapter types and schedule remediation.


========================================================================


Scenario 77: Time-Sync / NTP Mis-Configuration Leading to Authentication Failures & VM Guest Crashes


In a vSphere cluster, guest OS authentication failures (e.g., Kerberos) started appearing intermittently, and time-sensitive applications reported errors. Some VMs exhibited clock drift relative to the host or other services, causing licences, clustered services or replication to behave erratically. Investigation found hosts/VMs lacked consistent NTP/time synchronisation.


Symptoms:

Guest OS logs show time mismatch warnings or authentication failures such as “ticket expired” or “time skew”.

VMs’ internal clocks visibly drift compared to host or external time source.

Applications relying on time (licensing servers, clustered services, replication) show failures or unexpected behaviour.


Root cause analysis:

Time synchronisation is a commonly overlooked yet critical component in virtualised infrastructures. If hosts or guests drift in time, authentication, clustering, licensing, replication and other services may degrade or fail. The “resource constraints / configuration errors” category of issues for VMware includes time-sync mis-config as a hidden root cause.


Troubleshooting steps:


On each ESXi host: check NTP/time configuration (via vSphere Host → Manage → Time & Location).

For each VM: check guest OS date/time and compare with host/physical time.

Review VMware Tools settings: is guest-host time sync enabled? Is the guest OS also configured with its own NTP?

Check logs for time mismatch, authentication failures, replication issues correlating with time skew.


Solution:

Standardise NTP/time-sync configuration across hosts; ensure a reliable external time source is used.

Decide a time-sync strategy for guest VMs: either rely on host time or configure independent NTP inside guest OS depending on requirements.

Monitor time drift across hosts and VMs; set alert thresholds (e.g., > X seconds drift).

Integrate time-sync checks into regular health/maintenance routines.


=======================================================================

Scenario 78: VM Hardware Version Mismatch Across Hosts Preventing vMotion & DRS Efficiency


In a cluster made up of hosts at different versions (some older, some upgraded), some VMs had their virtual hardware version upgraded to latest compatibility level. When the DRS cluster attempted to migrate VMs, certain migrations failed because some hosts couldn’t support the newer hardware version of those VMs. Over time, this mismatch reduced cluster flexibility and forced manual migrations. Compatibility mismatch is frequently referenced as a common VMware challenge.


Symptoms:

vMotion or DRS migration tasks fail with errors like “hardware version incompatible” or “host does not support virtual hardware version”.

Some hosts show VMs whose virtual hardware version is higher than that host supports.

DRS balancing or automated migrations exclude certain VMs or fail repeatedly.


Root cause analysis:

Every VM has a defined “virtual hardware version” (compatibility level) which corresponds to the host/cluster version. If you upgrade the VM version but don’t ensure all hosts support it, you limit migration flexibility and cluster mobility.


Troubleshooting steps:

For each VM: check its virtual hardware version via VM summary/settings.

For each host: verify supported virtual hardware versions via host version/HCL.

Search migration failure logs for messages referencing hardware version support or compatibility.

Inventory cluster: check hosts and VMs, identify mismatches and which VMs cannot migrate freely.


Solution:

Harmonise host versions (and capabilities) across the cluster or segment hosts into compatibility sub-clusters.

Plan VM hardware version upgrades only after verifying host support.

For VMs needing full mobility, avoid upgrading hardware version beyond lowest common host capability.

inventory tools or scripts to flag VMs whose hardware version exceeds cluster minimum supported version.

=======================================================================

Scenario 79: Storage Path Fail-over Not Configured Leading to I/O Interruptions During Maintenance

During scheduled storage array maintenance (where one Fibre-Channel path was disabled), one ESXi host experienced I/O timeouts and VMs became unresponsive until the path came back online. Investigation revealed that multipathing/alternate paths were mis-configured—when the primary path failed, no secondary path engaged. Shared-storage path fail-over mis-config is a widely reported cause of availability/performance issues.


Symptoms:

During a known maintenance window or path failure, one or more hosts show I/O errors and hang/slow VMs.

Logs on host show “path down” or “device unreachable” messages.

In vCenter, datastore shows alarms or hosts show datastore inaccessible momentarily.


Root cause analysis:

In shared-storage/virtualised environments, multipathing ensures redundancy of storage paths. If only one path is active or fail-over is mis-configured, maintenance or path fail results in I/O interruption. Hardware/driver path issues are frequent sources of VMware performance/availability incidents.


Troubleshooting steps:

On host: run esxcli storage core path list or esxcli storage nmp device list to check per-LUN path state and count of active paths.

Confirm each datastore has more than one active path, and alternate paths are flagged for fail-over.

Review host logs for recent maintenance/fail-over events and path failures.

Check multipathing policy (Round Robin, Fixed) and verify vendor best-practices used.


Solution:

Configure correct multipathing: at least 2 physical paths per datastore, verify active/standby states and proper fail-over settings.

Prior to maintenance, validate all hosts have redundant paths; if not, migrate VMs or remediated hosts.

Monitor path status: send alerts if only one path active or path count drops.


========================================================================


Scenario 80: VM Memory Over-commit Without Reservations Leads to Degraded Performance Under Peak Load

As part of cost-optimisation, the virtual infrastructure team increased VM density per host (more VMs per physical machine) without adjusting memory reservations or monitoring balloon/swapping metrics. When a peak workload day arrived, some VMs experienced high memory ballooning and swapping, guest OS response degraded, and application latency spiked. Memory over-commit without proper reservation is a common root cause for performance issues in virtual environments.


Symptoms:

Host overall memory usage appears moderate, but certain VMs show high “Ballooned Memory” or “Swapped Memory” metrics in vCenter.

Guest OS inside VM shows paging/swap behavior, delays, or slow response.

Applications inside VMs respond slower than expected despite host having apparent capacity.


Root cause analysis:

Memory over-commit allows assigning more memory to VMs than physical RAM available, but if reservations/limits aren’t configured and demand peaks, the hypervisor uses ballooning or swapping which degrades performance significantly. This ties into resource-constraint issues common in VMware environments.


Troubleshooting steps:

In vCenter: monitor host and VM memory metrics – “Ballooned Memory”, “Swapped Memory”, “Consumed vs Active”.

Identify VMs with high ballooning/swapping; correlate with guest OS paging/swapping activity.

Review resource-pool/Vm settings: are too many VMs on one host? Are reservations set appropriately?

Check host consolidation ratio and memory headroom; evaluate if more density is safe.


Solution:

Right-size VMs: allocate memory based on actual usage rather than “just in case”.

Set reservations for critical VMs so they are guaranteed memory and avoid ballooning/swap.

Monitor balloon/swap metrics and set alerts when thresholds exceeded (e.g., ballooning > 20%).

If over-committed, consider reducing number of VMs per host or adding memory capacity.

========================================================================

Scenario 81: Storage Array Firmware or Driver Mismatch Causing Intermittent I/O Errors

After upgrading hosts in one cluster, several VMs began showing intermittent I/O timeouts and “host datastore inaccessible” errors. Investigation revealed that the storage array firmware and host HBA driver versions were not certified for the upgraded ESXi version. According to VMware performance-bottleneck guidance, storage controller/firmware mismatches are common root causes.



Symptoms:

VMs report errors like “scsiDeviceAsserted” or “path lost” or “datastore not accessible” intermittently.

Performance charts show sudden spikes in storage latency or I/O queue depth.

Hosts log HBA driver warnings or firmware mismatch notices.


Root cause analysis:

When host software is upgraded but storage controller firmware or host HBA drivers lag behind or are unsupported, the storage subsystem may behave unpredictably. I/O delays, path resets or device assertion errors may result. Storage/hardware mismatches are frequently listed among key VMware infrastructure issues.


Troubleshooting steps:

Review host logs (vmkernel.log, vmkwarning.log) for HBA or storage controller driver/firmware mismatch warnings.

On host, check HBA driver version and firmware version against VMware HCL/storage vendor compatibility list.

Correlate I/O error events with maintenance or upgrade windows.

Check snapshot or rebuild backlog in storage array—performance may degrade during such events.


Solution:

Coordinate host upgrade with storage firmware/driver updates—only upgrade host after storage path is certified.

Maintain inventory of HBA firmware/driver versions across hosts and enforce schedule for updates.

Monitor I/O latency and error counters; set alerts for path resets or assertion events.

==============================================================

Scenario 82: VM Host Configuration Drift Causing Cluster Imbalance & DRS Inefficiency


Over time, configuration settings (such as CPU power management, NUMA settings, network teaming) diverged between hosts in a cluster. As a result, some hosts became under-utilised or overloaded, DRS balancing failed to migrate properly, and VM placement became inconsistent. Governance on host configuration drift is flagged as a major issue.


Symptoms:

Some hosts show consistent over-utilisation while others are idle, despite load being balanced by DRS.

DRS recommendations show many VMs pinned to certain hosts or migration fails without apparent reason.

Performance metrics vary host-to-host for similar workloads; settings differ.


Root cause analysis:

Configuration drift means hosts no longer present a uniform environment. Features like DRS, vMotion and Load-Balancing expect homogenous host configurations. When drift occurs, cluster behavioural assumptions break and you get inefficient distribution or stuck migrations.


Troubleshooting steps:

Inventory host configuration settings: BIOS power management, NUMA topology, NIC teaming, VMkernel adapter setup.

Compare hosts side-by-side to find differences.

Check DRS logs and migration failure messages—are they tied to host capability mismatch?

Assess host utilisation and DRS recommendations for anti-patterns (e.g., VMs refusing migration due to host mismatch).


Solution:

Standardise host configurations and enforce baseline/hardening templates for every host build.

Use change control to manage host configuration changes and track drift.

Regularly audit host settings and align them to baseline; remediate any deviations.

Monitor DRS/cluster health and fix hosts which diverge from cluster norm.


========================================================================


Scenario 83: vMotion Failure Due to VM Snapshot Present / Consolidation Needed

During a maintenance window, attempts to vMotion several VMs failed with errors citing “snapshot chain too deep” or “consolidation required”. It was found that those VMs had stale snapshots or required consolidation, which prevented successful vMotion or storage vMotion. Issues with snapshot/chain depth and migration are documented in VMware performance guidance.


Symptoms:

vMotion/storage vMotion tasks report failure with “Snapshot consolidation required” or “Cannot migrate because snapshot present”.

In VM’s Snapshot Manager: no visible snapshots, but status shows “Needs consolidation”.

Storage latency high on datastore hosting the VM; snapshot delta files large or old.


Root cause analysis:

VM migration operations (vMotion/storage vMotion) rely on clean disk state and manageable snapshot chains. If there’s an orphaned snapshot or consolidation required, migration may be blocked or significantly delayed. This falls under snapshot management issues—a common tripwire in VMware environments.


Troubleshooting steps:


For affected VMs: check Snapshot Manager for visible snapshots; also check VM’s folder for large delta redolog files.

Attempt consolidation: in vSphere Client, right-click VM > Snapshot > Consolidate; monitor for success.

Verify that datastore hosting VM has sufficient free space and I/O headroom.

Review migration error logs to capture specific snapshot/consolidation error codes.


Solution:

Clean up snapshots: remove old, unnecessary snapshots; enforce retention policy.

Before migration, ensure VMs are in healthy snapshot state (no consolidation needed).

Monitor and alert on “Needs consolidation” status periodically.

Update maintenance/upgrade checklist to include snapshot health check before vMotion window.

================================================================

Scenario 84: Improper VM Isolation in Resource Pools Leading to Noisy-Neighbour Impact


In a shared virtual cluster, several resource pools were configured to allow “Unlimited” CPU/Memory for some VMs. Over time a database VM saturated resources, causing other business-critical VMs to suffer slow performance. Troubleshooting articles cite resource contention/noisy-neighbour effects as a top virtualization issue.


Symptoms:


Non-critical VMs appear to run fine, but business-critical VMs show sluggish response, high CPU Ready, memory ballooning.

Resource pool charts: one pool shows sustained high consumption, other pools starve.

Host metrics: CPU Ready time elevated, memory paging high, despite overall utilisation not showing full saturation.


Root cause analysis:


In a virtualised environment sharing resources, one VM (or resource pool) can dominate if not constrained, starving others—“noisy-neighbour” effect. Without proper resource controls (shares, limits, reservations), critical workloads suffer. This is a classic resource-contention scenario.


Troubleshooting steps:

Identify VMs with high CPU Ready or memory balloon rates via performance charts.

Review resource pool settings: shares, reservations, limits for all pools and VMs.

Correlate performance degradation of business-critical VMs with increased activity in other resource pools.

Verify host physical resources available and utilisation metrics.


Solution:


Configure resource pools with appropriate reservations, limits/shares to prioritise critical workloads.

For VMs requiring high performance, apply reservations to guarantee resources.

Monitor CPU Ready time, memory reclamation metrics, and set alerts for noisy-neighbour behaviour.

Educate teams provisioning VMs about job-classification and ensure uncontrolled VMs are not placed in critical workload pools.


========================================================================


Scenario 85: Storage Tiering Mis-Policy Moves Active Data to Cold Tier Causing Latency Spikes

An organisation implemented storage tiering to optimise cost: hot data on SSDs, cold on slower HDD. After the automation engine kicked in during business hours, several VMs experienced increased latency and slower response times. It turned out the tiering policy promoted/demoted incorrectly and moved active data to a slower tier while “cold” activity mis-classified. Storage tiering mis-configuration is flagged among common performance issues.


Symptoms:


Certain VMs show intermittent high storage latency despite capacity headroom.

Storage monitoring shows data movement from fast tier to slow tier coinciding with latency events.

Datastore I/O queue depth spikes on slower tier already servicing new “hot” data.


Root cause analysis:

Automated tiering systems are beneficial, but only when policy and classification are correct. In virtualised workloads, I/O patterns may change rapidly; mis-classification may move “hot” data to slow tier, causing performance hits. Understanding bottlenecks emphasises the chain: the slowest component dictates performance.


Troubleshooting steps:

Monitor storage tier movement logs: check when data was moved from fast to slow tier, and map to performance drop time.

Check storage latency, queue depth for datastores in both tiers (fast vs slow).

Review tiering policy: what defines “cold” data, what triggers movement, any schedules.

Identify VMs impacted: map to moved data to slow tier and check if those VMs had sudden I/O demand increase.


Solution:

Refine tiering policy: more conservative thresholds for demotion, schedule movement during off-peak hours.

Mark critical VM data to stay on fast tier (exclusion rule).

Monitor storage I/O latency and queue depth continuously; alert when movement coincides with performance drop.

Review tiering results periodically and adjust policies based on real I/O patterns.


=======================================================================


Scenario 86: Mis-used Resource Pools Causing Poor VM Prioritisation and Performance

In a converged cluster environment, different teams created resource pools for their VMs, but many had “Unlimited” settings or mis-allocated CPU/memory shares. Over time, one resource pool dominated while critical business-workload VMs in other pools got starved. The concept of resource pools and their correct configuration is discussed in VMware documentation.


Symptoms:


Business-critical VMs in one resource pool show high CPU Ready, memory ballooning, or latency despite host appearing under-utilised.

Resource-pool usage charts show one pool consuming large share of resources; other pools idle.

DRS/migration behaviour odd: some VMs get moved off overloaded hosts while some remain stuck in low-priority pools.


Root cause analysis:

Resource pools allow grouping of VMs and allocation of Shares/Reservations/Limits for CPU/Memory. Mis-configuration (e.g., Unlimited pools, incorrect share settings) leads to noisy-neighbour or priority inversion issues. The resource-pool construct is often misunderstood.


Troubleshooting steps:

Review all resource pools: check their CPU/Mem Shares, Reservations, Limits; ensure they reflect business priorities.

For each VM, check which pool it's in and what its entitlement is under current demand.

Monitor performance metrics: CPU Ready, memory balloon/swapping, share entitlement vs usage.

Identify whether host imbalance arises from one pool dominating resources.


Solution:

Re-design resource pool hierarchy so that critical workloads have guaranteed reservation and high shares.

Set sensible limits for noncritical pools to avoid resource hogging.

Monitor resource-pool usage and set alerts when a pool exceeds expected consumption or unfairly starves others.

========================================================================


Scenario 87: Oversight in VMware vSAN Rebuild/Repair Timer Causing Prolonged Degraded State

In a vSAN cluster, a disk group failed and although the cluster entered degraded mode, the automatic rebuild timer was long and spare capacity minimal. Consequently performance degraded for a prolonged period, with high latency and degraded redundancy. VMware’s vSAN failure scenarios doc covers similar cases.


Symptoms:

vSAN health shows “Degraded object” or “Absent component” for extended periods.

VM I/O latency increases, storage performance drops.

Cluster alarms about reduced redundancy but staff assume rebuild will fix automatically (slowly).


Root cause analysis:

vSAN uses automated repair mechanisms triggered after a device fails. If rebuild timer is mis-set or spare capacity insufficient, the cluster remains in degraded mode for too long, increasing risk and performance impact.


Troubleshooting steps:

Use vSAN Health to check component status and rebuild backlog.

Check disk group spare capacity and whether timer for rebuild is set appropriately.

Monitor I/O latency on vSAN datastore; correlate with degraded component period.


Solution:

Configure rebuild timers/tolerances suited to business SLA (e.g., shorter delay).

Ensure enough spare capacity in vSAN design so repair can complete without impacting live workloads.

Monitor vSAN health proactively; set alerts when objects are degraded for more than X minutes.

========================================================================

Scenario 88: Integration of vSphere with Microsoft Active Directory Exposing Hypervisor Risk

An organization joined ESXi hosts and vCenter to Active Directory for convenience. A security review (by e.g. Mandiant) flagged this as an attack path: compromising AD credentials could give attacker hypervisor control. The risk of AD integration is described in a blog by Google Cloud/Threat Intelligence.


Symptoms:

ESXi hosts are domain-joined; vCenter uses AD groups for admin access.

No MFA on AD accounts used for vSphere access.

Audit shows lack of segregation between AD privileges and hypervisor access.


Root cause analysis:

While AD integration simplifies login, it increases attack surface: AD compromise can lead to hypervisor compromise. Hypervisor environment must be secured with least privilege, MFA, role-based controls.


Troubleshooting steps:


Review host/vCenter authentication method: are hosts domain-joined? Are AD groups used for vSphere admin?

Check AD group membership and privileges assigned to hosts/vCenter.

Look for missing MFA, auditing gaps, overly broad privileges.


Solution:


Consider isolating vSphere admin domain from general AD or use just vCenter with dedicated accounts.

Enforce MFA, least-privilege rights, dedicated admin accounts for hypervisor access.

Audit regularly AD to hypervisor mappings and privilege drift.

===================================================================

Scenario 89: Mis-Configuration of Time / NTP Across Hosts and Guests Causing Application Failures

Hosts had inconsistent time settings, some guests relied on host clock, others on internal NTP. As a result, distributed applications and authentication systems failed intermittently. Time and synchronization issues are documented as key performance/availability risks.


Symptoms:


Guest OS logs show time drift or authentication errors.

Distributed workloads (clustered databases, replication) show time sync warnings.

Host clocks differ significantly; some VMs show past/future time stamps.


Root cause analysis:


Time synchronization is critical for authentication, VM management, replication. Inconsistent configurations (host vs guest NTP, VMware Tools sync) lead to cascading failures.


Troubleshooting steps:

Check each host’s NTP/time source config; ensure uniform.

Check VMs: which have host time sync enabled vs their own NTP.

Review guest OS logs for time drift, Kerberos failures, licensing errors.


Solution:


Define and enforce time sync policy: hosts sync to reliable external NTP; VMs either sync to host or dedicated NTP depending on need.

Monitor drift; set alert if any host/VM drifts > X seconds.

Include time-sync validation in pre-upgrade/maintenance checklists.

Narrative: “Our SQL cluster failed at peak — and the root cause was that one host clock was 45 seconds off.”

========================================================================

Scenario 90: VM Migration (vMotion) Fails Because of Hidden Snapshots or Consolidation Required

During a host or cluster maintenance window, multiple vMotion tasks failed with snapshot-related errors. It was found that certain VMs had orphaned snapshots or required consolidation, blocking migration. Guides on VMware troubleshooting list snapshots & migration errors as common issues.


Symptoms:

vMotion tasks fail with errors about “snapshot chain too deep”, “consolidation required” or “cannot migrate due to snapshot”.

Snapshot Manager shows no snapshots but VM status indicates “Needs Consolidation”.

Storage latency or free-space alerts for datastore hosting such VMs.


Root cause analysis:

VM migration relies on clean disk state and manageable snapshot chains. Hidden/orphan snapshots prevent successful migrations and degrade performance.

Troubleshooting steps:

Identify VMs with “Needs Consolidation” status or large delta files in datastore.

Review migration failure logs for snapshot-specific error messages.

Check datastore free space and I/O queue depth for VMs with hidden snapshot chains.


Solution:

Consolidate snapshots for affected VMs; delete unnecessary snapshots and enforce retention limits.

Prior to migration/maintenance, run snapshot health check for VMs.

Monitor for orphan delta files and alert if present.

==================================================================


Scenario 91: Mis-used Resource Pools Causing Poor VM Prioritization and Performance


In a cluster environment, various teams each created their own resource pools for VMs. However many of these pools were configured with “Unlimited” settings or default/unadjusted shares. Over time one pool dominated resources while business-critical VMs in other pools got starved. Articles note that resource-pool misuse is a common performance pitfall.


Symptoms:

Business-critical VMs in one pool showing high CPU Ready, memory ballooning or latency despite host capacity.

Resource pool charts show one pool consuming large share of compute/memory; other pools are starved.

DRS/migration behavior odd: some VMs pinned to hosts or migration fails because of pool priority mismatch.


Root cause analysis:

Resource pools allow logical partitioning of compute/memory resources (CPU/Memory shares, reservations, limits). If configured poorly (e.g., one pool has many VMs but same or higher share than a smaller important pool), you end up with “noisy-neighbour” effects or priority inversion. The share/reservation concepts are easily misunderstood.


Troubleshooting steps:

Review all resource pools: examine CPU/Mem Shares, Reservations, Limits for each pool and VM.

For each VM, check which pool it is in and what the effective entitlement is (Shares ÷ # of VMs).

Monitor CPU Ready, memory ballooning/swapping, host utilisation and resource-pool consumption.

Correlat performance issues with pool settings and VM placement.


Solution:


Re-design resource pool hierarchy so critical workloads are guaranteed resources (via reservations) and have higher share priority.

Set limits on non-critical pools so they cannot dominate resources.

Monitor resource pool usage and set alerts for pool(s) consuming unexpectedly high share of resources.

Educate teams provisioning VMs about correct resource pool use, and review pool settings periodically.

========================================================================


Scenario 92: Oversight in vSAN Rebuild/Repair Timer Causing Prolonged Degraded State


In a cluster using VMware vSAN, a drive group failure occurred. The cluster entered degraded mode, but because the repair timer and spare capacity were insufficient, the rebuild delayed and business-critical VMs experienced elevated latency for an extended period. The design assumption that vSAN would rebuild quickly turned out to be optimistic.


Symptoms:

vSAN health showing “Degraded object” or “Absent component” for a prolonged duration.

VM I/O latency increases; datastore performance suffers.

Alerts about reduced redundancy, but operations assume self-healing will fix fast.


Root cause analysis:

vSAN’s automated rebuild mechanism depends on spare capacity and repair/timeout settings. If the system doesn’t have enough spare disks, or the repair timer is too long, the cluster remains in degraded state longer than acceptable. Designs often assume “automatic repair” without verifying capacity or timer.


Troubleshooting steps:

Use vSAN Health to identify component failures and rebuild backlogs.

Check spare capacity of disk groups and the configuration of the rebuild/repair timer.

Monitor VM latency and correlate it with the degraded status time window.


Solution:

Adjust vSAN repair timers to match SLA (e.g., shorten delay before rebuild starts).

Ensure sufficient spare capacity in design so rebuild can proceed without impacting live workloads.

Monitor vSAN health proactively; set alerts when objects are degraded beyond threshold.


================================================================


Scenario 93: Integration of vSphere with Active Directory Exposing Hypervisor Risk

An organisation joined ESXi hosts and vCenter to its corporate AD for convenience. A security review flagged this as an attack path: a compromised AD account could lead to hypervisor access. The risk of hypervisor authentication exposure is increasingly discussed in virtualization security advisories.


Symptoms:

ESXi hosts are domain-joined; vCenter admin roles mapped to AD groups.

No mandatory MFA on AD accounts used for hypervisor access.

Audit shows broad AD group membership and privilege drift giving many users hypervisor rights.


Root cause analysis:

While AD integration simplifies login management, it increases attack surface: AD compromise = hypervisor compromise. Temporary or unexpected privileges, lack of least-privilege, and lack of hardened separation amplify risk.


Troubleshooting steps:

Review host & vCenter authentication method: domain joined vs local; AD group to role mapping.

Audit privilege assignments: which AD accounts/groups have vSphere/host access? Are MFA/enforcement applied?

Check logs for unusual privilege assignments or failed login attempts; review membership drift.


Solution:

Consider isolating vSphere infrastructure from general AD or use dedicated identity domain/solution.

Enforce least-privilege, use MFA, dedicated admin accounts for hypervisor access only.

Periodically audit AD → hypervisor privilege mapping and enforce role separation.


========================================================================


Scenario 94: Mis-Configuration of Time / NTP Across Hosts & Guests Causing Application Failures

Hosts and VMs in a cluster had inconsistent NTP/time sync configurations: some hosts were using incorrect time sources, some VMs synced to host clock, others used their own sub-optimal NTP. Applications sensitive to time (Kerberos, replication, licensing) started failing. Time sync issues are often underestimated yet pose real risk.


Symptoms:

Guest OS logs show time skew errors or authentication failures.

Time stamps in logs across hosts/VMs differ significantly.

Applications (replication, clustering, licensing) behaving erratically or failing.


Root cause analysis:

Time synchronisation is foundational. If hosts drift in time or guests are mismatched, many infrastructure services (authentication, backups, cluster coordination) can fail. Virtual environments often neglect consistent time configuration.


Troubleshooting steps:

Check each ESXi host’s NTP configuration (via vSphere host settings) and verify they sync to reliable external sources.

For each VM: check time-sync settings (host time sync vs guest NTP) and compare guest clock vs host clock.

Review application/OS logs for time mismatch errors, license expiration, replication delays.


Solution:

Standardise time configuration: hosts sync to trusted NTP servers; VMs either host-sync or use approved guest NTP depending on role.

Monitor time drift across hosts and VMs; alert if drift > X seconds.

Include time-sync validation in regular health checks and pre-maintenance checklists.

==================================================================


Scenario 95: VM Migration (vMotion) Fails Because of Hidden Snapshots or Consolidation Required

During a host maintenance window, numerous vMotion/Storage vMotion tasks failed with errors referencing “snapshot chain too deep” or “consolidation required”. Investigation showed that certain VMs had hidden/orphaned snapshots not visible in Snapshot Manager. Migration was blocked and downtime extended. Snapshot-management/migration issues are a common source of workflow failure.


Symptoms:

vMotion tasks fail with errors such as “Unable to migrate VM – snapshot present” or “Consolidation needed”.

VM’s Snapshot Manager shows no snapshots, yet VM displays “Needs consolidation” status.

Datastore free space low; latency high for VMs involved.


Root cause analysis:

VM migration requires clean disk state and manageable snapshot chains. Hidden or orphaned snapshots (delta files) block operations and degrade performance. Without snapshot hygiene, migrations and storage operations fail.


Troubleshooting steps:

Identify VMs with status “Needs Consolidation” or large delta VMDK files on datastore.

Review migration error logs for snapshot-specific codes.

Validate datastore free space and I/O metrics for impacted VMs.

Attempt manual consolidation and verify success before further migration.


Solution:

Implement snapshot governance: limit age/size of snapshots, delete unneeded ones, automate check of orphan deltas.

Prior to migration/maintenance, run snapshot-health checks for each VM.

Monitor for hidden snapshot chains via storage scanning and set alerts.

========================================================================


Scenario 96: Storage Array Firmware or Driver Mismatch Causing Intermittent I/O Errors

After upgrading hosts in one cluster, several VMs began showing intermittent I/O timeouts and “host datastore inaccessible” errors. Investigation revealed that the storage array firmware and host HBA driver versions were not certified for the upgraded ESXi version. According to VMware performance-bottleneck guidance, storage controller/firmware mismatches are common root causes.


Symptoms:


VMs report errors like “scsiDeviceAsserted” or “path lost” or “datastore not accessible” intermittently.

Performance charts show sudden spikes in storage latency or I/O queue depth.

Hosts log HBA driver warnings or firmware mismatch notices.


Root cause analysis:

When host software is upgraded but storage controller firmware or host HBA drivers lag behind or are unsupported, the storage subsystem may behave unpredictably. I/O delays, path resets or device assertion errors may result. Storage/hardware mismatches are frequently listed among key VMware infrastructure issues.


Troubleshooting steps:

Review host logs (vmkernel.log, vmkwarning.log) for HBA or storage controller driver/firmware mismatch warnings.

On host, check HBA driver version and firmware version, and compare against VMware HCL/storage vendor compatibility list.

Correlate I/O error events with maintenance or upgrade windows.

Check snapshot or rebuild backlog in storage array—performance may degrade during such events.


Solution:

Coordinate host upgrade with storage firmware/driver updates—only upgrade host after storage path is certified.

Maintain inventory of HBA firmware/driver versions across hosts and enforce schedule for updates.

Monitor I/O latency and error counters; set alerts for path resets or assertion events.


================================================================


Scenario 97: VM Host Configuration Drift Causing Cluster Imbalance & DRS Inefficiency

Over time, configuration settings (for example CPU power management, NUMA settings, network teaming) diverged between hosts in a cluster. As a result, some hosts became under-utilised or overloaded, DRS balancing failed to migrate properly, and VM placement became inconsistent. Governance on host configuration drift is flagged as a major issue.


Symptoms:

Some hosts show consistent over-utilization while others are idle, despite load being balanced by DRS.

DRS recommendations show many VMs pinned to certain hosts or migration fails without apparent reason.

Performance metrics vary host-to-host for similar workloads; settings differ.


Root cause analysis:

Configuration drift means hosts no longer present a uniform environment. Features like DRS, vMotion and Load-Balancing expect homogenous host configurations. When drift occurs, cluster behavioural assumptions break and you get inefficient distribution or stuck migrations.


Troubleshooting steps:

Inventory host configuration settings: BIOS power management, NUMA topology, NIC teaming, VMkernel adapter setup.

Compare hosts side-by-side to find differences.

Check DRS logs and migration failure messages—are they tied to host capability mismatch?

Assess host utilisation and DRS recommendations for anti-patterns (e.g. VMs refusing migration due to host mismatch).


Solution:

Standardise host configurations and enforce baseline/hardening templates for every host build.

Use change control to manage host configuration changes and track drift.

Regularly audit host settings and align them to baseline; remediate any deviations.

Monitor DRS/cluster health and fix hosts which diverge from cluster norm.

=====================================================

Scenario 98: vMotion Failure Due to VM Snapshot Present / Consolidation Needed


During a maintenance window, attempts to vMotion several VMs failed with errors citing “snapshot chain too deep” or “consolidation required”. It was found that those VMs had stale snapshots or required consolidation, which prevented successful vMotion or storage vMotion. Issues with snapshot/chain depth and migration are documented in VMware performance guidance.


Symptoms:

vMotion/storage vMotion tasks report failure with “Snapshot consolidation required” or “Cannot migrate because snapshot present”.

In VM’s Snapshot Manager: no visible snapshots, but status shows “Needs consolidation”.

Storage latency high on datastore hosting the VM; snapshot delta files large or old.


Root cause analysis:

VM migration operations (vMotion/storage vMotion) rely on clean disk state and manageable snapshot chains. If there’s an orphaned snapshot or consolidation required, migration may be blocked or significantly delayed. This falls under snapshot management issues—a common trip-wire in VMware environments.


Troubleshooting steps:

For affected VMs: check Snapshot Manager for visible snapshots; also check VM’s folder for large delta redolog files.

Attempt consolidation: in vSphere Client, right-click VM > Snapshot > Consolidate; monitor for success.

Verify that datastore hosting VM has sufficient free space and I/O head-room.

Review migration error logs to capture specific snapshot/consolidation error codes.


Solution:


Clean up snapshots: remove old, unnecessary snapshots; enforce retention policy.

Before migration, ensure VMs are in healthy snapshot state (no consolidation needed).

Monitor and alert on “Needs consolidation” status periodically.

Update maintenance/upgrade checklist to include snapshot health check before vMotion window.


==================================================================


Scenario 99: Improper VM Isolation in Resource Pools Leading to Noisy-Neighbour Impact

In a shared virtual cluster, several resource pools were configured to allow “Unlimited” CPU/Memory for some VMs. Over time a database VM saturated resources, causing other business-critical VMs to suffer slow performance. Troubleshooting articles cite resource contention/noisy-neighbor effects as a top virtualization issue.


Symptoms:


Non-critical VMs appear to run fine, but business-critical VMs show sluggish response, high CPU Ready, memory ballooning—even though host appears not fully utilised.

Resource pool charts: one pool shows sustained high consumption, other pools starve.

Host metrics: CPU Ready high, memory reclamation high, despite available capacity.


Root cause analysis:


In a virtualised environment sharing resources, one VM (or resource pool) can dominate if not constrained, starving others—“noisy-neighbour” effect. Without proper resource controls (shares, limits, reservations), critical workloads suffer.


Troubleshooting steps:


Identify VMs with high CPU Ready or memory balloon rates via performance charts.

Review resource pool settings: shares, reservations, limits for all pools and VMs.

Correlate performance degradation of business-critical VMs with increased activity in other resource pools.

Verify host physical resources available and utilisation metrics.


Solution:

Configure resource pools with appropriate reservations, limits/shares to prioritise critical workloads.

For VMs requiring high performance, apply reservations to guarantee resources.

Monitor CPU Ready time, memory reclamation metrics, and set alerts for noisy-neighbour behaviour.

Educate teams provisioning VMs about job-classification and ensure uncontrolled VMs are not placed in critical workload pools.

=====================================================================


Scenario 100: Storage Tiering Mis-Policy Moves Active Data to Cold Tier Causing Latency Spikes

An organization implemented storage tiering to optimise cost: hot data on SSDs, cold on slower HDD. After the automation engine moved “cold” data into slower tier during business hours, several VMs experienced increased latency and slower response times. It turned out the tiering policy mis-classified active data and moved it to slower tier, causing performance hits. Storage tiering mis-configuration is flagged among common performance issues.


Symptoms:

Certain VMs show intermittent high storage latency despite capacity head-room.

Storage monitoring shows data movement from fast tier to slow tier coinciding with latency events.

Datastore I/O queue depth spikes on slower tier already servicing new “hot” data.


Root cause analysis:

Automated tiering systems are beneficial, but only when policy and classification are correct. In virtualised workloads, I/O patterns may change rapidly; mis-classification may move “hot” data to slow tier, causing performance hits. Understanding bottlenecks emphasises the chain: the slowest component dictates performance.


Troubleshooting steps:

Monitor storage tier movement logs: check when data moved from fast to slow tier and map to performance drop time.

Check I/O latency and queue depth for datastores in both tiers (fast vs slow).

Review tiering policy: what defines “cold” data, what triggers movement, is movement occurring during business hours?

Identify VMs impacted: map to moved data to slow tier and check if those VMs had recent increased I/O demand.


Solution:

Refine tiering policy: more conservative thresholds for demotion, schedule movement during off-peak hours.

Exclude critical workloads from tiering or mark their data as “always on fast tier.”

Monitor storage I/O latency and queue depth continuously; alert when movement coincides with performance drops.

Review tiering outcomes periodically and adjust policies based on real workload behavior.


 
 
 

Recent Posts

See All
Automation using Power Cli

<# PowerCLI - vSphere Full Monitoring Automation File: PowerCLI - vSphere Full Monitoring Automation.ps1 Purpose: Complete, production-ready PowerCLI automation script collection for comprehensive vSp

 
 
 

Comments

Rated 0 out of 5 stars.
No ratings yet

Add a rating
bottom of page